Exam Details
ESE (IES)Electronics & Communication Engineering TECHNICAL 2017
Review the key details, then start the test when you are ready. You can also open the full package to see related papers.
Questions
150
Duration
180 mins
Package
ESE & GATE EC - Previous Year Papers
Paper pattern & analysis
Filter this paper by subject, topic or subtopic. Every graph updates from the selected questions.
Topic distribution
Subtopic distribution
Difficulty distribution
150questions
Medium
111
74%
Hard
27
18%
Easy
12
8%
Question type distribution
150questions
Multiple Choices
150
100%
Instructions
Demo Instruction
Syllabus
Sample
Sample questions from this paper
Questions are selected across the paper subjects wherever the paper contains that variety.
2017 · Unclassified
ESE (IES)Electronics & Communication Engineering TECHNICAL 2017
Consider the following statements: 1) Type-I superconductors undergo abrupt transition to the normal state above a critical magnetic field. 2) Type-II superconductors are highly technologically useful super-conductors because the incidence of a second critical field in them is useful in the preparation of high field electromagnets. Which of the above statements is/are correct?
2017 · Unclassified
ESE (IES)Electronics & Communication Engineering TECHNICAL 2017
Consider the following statements: 1) Metal conductors have more R at higher temperatures. 2) Tungsten can be used as a resistance wire. 3) A superconductive material is one which has practically zero resistance. Which of the above statements are correct?
2017 · Unclassified
ESE (IES)Electronics & Communication Engineering TECHNICAL 2017
Consider the following statements regarding precision in measurements of a quantity: 1) Precision is the measure of the spread of the incident errors. 2) precision is independent of the realizable correctness of the measurement. 3) Precision is usually described in terms of number of digits used in the measurement by a digital instrument. Which of the above statements are correct?
2017 · Unclassified
ESE (IES)Electronics & Communication Engineering TECHNICAL 2017
Consider the following statements in connection with deflection-type and null-type instruments: 1) Null-type instruments are more accurate than the deflection-type ones. 2) Null-type of instrument can be highly sensitive compared to a deflection-type instrument. 3) Under dynamic conditions, null-type instruments are less preferred to deflection type instruments. 4) Response is faster in null-type instruments as compared to deflection-type instruments. Which of the above statements are correct?
2017 · Unclassified
ESE (IES)Electronics & Communication Engineering TECHNICAL 2017
A voltmeter having a sensitivity of reads 100 V on its 150 V scale when connected across at resistor of unidentified specifications in series with a milliammeter. When the milliammeter reads 5 mA, the error due to the loading effect of the voltmeter will be nearly
2017 · Unclassified
ESE (IES)Electronics & Communication Engineering TECHNICAL 2017
Consider the following statements: Sphere gap method of voltage measurement is used 1) for measuring r.m.s. value of a high voltage 2) for measuring peak value of a high voltage 3) as the standard for calibration purposes Which of the above statements are correct?