BHEL ET Electrical Engineering 2019

Review the key details, then start the test when you are ready. You can also open the full package to see related papers.

Questions 240
Duration 180 mins
Package ESE & GATE EE - Previous Year Papers

Paper pattern & analysis

Filter this paper by subject, topic or subtopic. Every graph updates from the selected questions.

Explore previous papers
Showing all 240 questions in this paper.

Subject distribution

No subject classification is available.

Topic distribution

No topic classification is available.

Subtopic distribution

No subtopic classification is available.

Difficulty distribution

Medium 143 59.6%
Hard 54 22.5%
Easy 43 17.9%

Question type distribution

Multiple Choices 240 100%

Instructions

Demo Instruction

Syllabus

Sample

Sample questions from this paper

Questions are selected across the paper subjects wherever the paper contains that variety.

1
2019 · Unclassified
BHEL ET Electrical Engineering 2019
For complete protection of a 3-phase line, how many phases and earth fault relays are required?
A
2 phases and 2 earth fault relays
B
2 phases and 1 earth fault relay
C
1 phase and 2 earth fault relays
D
3 phases and 1 earth fault relay
2
2019 · Unclassified
BHEL ET Electrical Engineering 2019
The area of a hysteresis loop for the magnetic material used in the rotor of a hysteresis motor should be:
A
medium
B
very large
C
very small
D
infinite
3
2019 · Unclassified
BHEL ET Electrical Engineering 2019
Two incandescent bulbs of rating 230 V, 100 W and 230 V 500 W are connected ¡u series across the mains. As a result what will happen?
A
500 W will glow brighter
B
100 W will glow brighter
C
neither will glow brighter
D
both will glow brighter
4
2019 · Unclassified
BHEL ET Electrical Engineering 2019
Determine the time of operation of a relay of rating 5 A. 2.2 s IDMT and having a relay setting of 125°, TMS = 0.6. It is connected to the supply circuit through a CT 400: 5 ratio. The fault current is 4000 A.
PSM: 2 5 8 10
Time: 10 8 3.2 2.5
A
1.89 s
B
1.87 s
C
1.93 s
D
1.92 s
5
2019 · Unclassified
BHEL ET Electrical Engineering 2019
A shift registers with its complement output (Q’) of the last stage connected to the D-input of the first stage is called:
A
twisted-ring counter
B
asynchronous counter
C
up-counter
D
synchronous counter
6
2019 · Unclassified
BHEL ET Electrical Engineering 2019
A 3-phase transformer rated for 336.6 kV is connected to a star delta and the current transformer on the LV side has a ratio of 500: 5. Determine the ratio of the current transformer on the HV side.
A
1900-01-03 17:26:10
B
C
D
1900-01-04 03:26:10