My Cart
Your Cart 0

    Your cart is empty.

  • Total (Amount) ₹0.00
Previous year question hub

Process Measurements and Instrumentation - Instrumentation and Process Control - Chemical Engineering Previous Year Questions

Practice Process Measurements and Instrumentation - Instrumentation and Process Control - Chemical Engineering previous year questions organised from real papers, with year-wise coverage and clear topic navigation.

12Papers
12Years
23Questions
1Topics

Process Measurements and Instrumentation question pattern

Every graph below is calculated only from this selection.

Questions by year

Compare question counts across years.

Difficulty distribution

How the classified questions are distributed by difficulty.

Easy 17 73.9%
Medium 6 26.1%

Question type distribution

MCQ, numerical, multiple-select and other formats found in these papers.

MCQ 18 78.3%
Numerical Answer Type (NAT) 3 13%
Fill in the blanks 1 4.3%
MSQ 1 4.3%

Subject weightage

Top subjects by unique question coverage.

Chemical Engineering
23 Qs

Most asked topics

Top topics across the included previous year papers.

Instrumentation and Process Control
23 Qs

Subtopic coverage

Top subtopics inside this exact selection.

Process Measurements and Instrumentation
23 Qs

Paper coverage

Question coverage for the most populated papers. Every active PYP paper remains listed below.

Chemical Engineering (CH) 2026
2 Qs
Chemical Engineering (CH) 2021
3 Qs
Chemical Engineering (CH) 2020
2 Qs
Chemical Engineering (CH) 2019
2 Qs
Chemical Engineering (CH) 2017
2 Qs
Chemical Engineering (CH) 2016
3 Qs
Chemical Engineering (CH) 2013
2 Qs
Chemical Engineering (CH) 2012
1 Qs
Chemical Engineering (CH) 2011
2 Qs
Chemical Engineering (CH) 2010
1 Qs
Chemical Engineering (CH) 2009
1 Qs
Chemical Engineering (CH) 2007
2 Qs

Included previous year papers

Newest papers appear first. Search these papers or sort by year and name.

Paper nameYearPDFAttempt
Chemical Engineering (CH) 20262026
2 questions in this view
2026
Chemical Engineering (CH) 20212021
3 questions in this view
2021
Chemical Engineering (CH) 20202020
2 questions in this view
2020
Chemical Engineering (CH) 20192019
2 questions in this view
2019
Chemical Engineering (CH) 20172017
2 questions in this view
2017
Chemical Engineering (CH) 20162016
3 questions in this view
2016
Chemical Engineering (CH) 20132013
2 questions in this view
2013
Chemical Engineering (CH) 20122012
1 questions in this view
2012
Chemical Engineering (CH) 20112011
2 questions in this view
2011
Chemical Engineering (CH) 20102010
1 questions in this view
2010
Chemical Engineering (CH) 20092009
1 questions in this view
2009
Chemical Engineering (CH) 20072007
2 questions in this view
2007

All Process Measurements and Instrumentation previous year questions

Practice every matching question in batches of 20, with every available option.

1
2007 · Chemical Engineering · Instrumentation and Process Control · Process Measurements and Instrumentation
Chemical Engineering (CH) 2007

An operator was told to control the temperature of a reactor at 60 °C. The operator set the set-point of the temperature controller at 60. The scale actually indicated 0 to 100% of a temperature range of 0 to 200 °C. This caused a runaway reaction by over-pressurizing the vessel, which resulted in injury to the operator. The actual set-point temperature was

Open complete paper
2
2007 · Chemical Engineering · Instrumentation and Process Control · Process Measurements and Instrumentation
Chemical Engineering (CH) 2007

The bias values for the two controllers, so that no offset occurs in either controller are

Open complete paper
3
2009 · Chemical Engineering · Instrumentation and Process Control · Process Measurements and Instrumentation
Chemical Engineering (CH) 2009
Which ONE of the following sensors is used for the measurement of temperature in a combustion process (T > 1800 °C) ?
Open complete paper
4
2010 · Chemical Engineering · Instrumentation and Process Control · Process Measurements and Instrumentation
Chemical Engineering (CH) 2010

Flow measuring instruments with different specifications (zero and span) are available for an application that requires flow rate measurements in the range of 300 litres/h to 400 litres/h. The appropriate instrument for this application is the ONE whose specifications are

Open complete paper
5
2011 · Chemical Engineering · Instrumentation and Process Control · Process Measurements and Instrumentation
Chemical Engineering (CH) 2011
Match the process parameters in Group I with the measuring instruments in Group II
GROUP IGROUP II
P. Flame temperature
Q. Composition of LPG
R. Liquid air temperature
I. Thermocouple
II. Radiation pyrometer
III. Gas chromatograph
Open complete paper
6
2011 · Chemical Engineering · Instrumentation and Process Control · Process Measurements and Instrumentation
Chemical Engineering (CH) 2011

The range of standard current signal in process instruments is 4 to 20 mA. Which ONE of the following is the reason for choosing the minimum signal as 4 mA instead of 0 mA?

Open complete paper
7
2012 · Chemical Engineering · Instrumentation and Process Control · Process Measurements and Instrumentation
Chemical Engineering (CH) 2012

A thermocouple having a linear relationship between 0 °C and 350 °C shows an emf of zero and 30.5 mV, respectively at these two temperatures. If the cold junction temperature is shifted from 0 °C to 30 °C, then the emf correction (in mV) is

Open complete paper
8
2013 · Chemical Engineering · Instrumentation and Process Control · Process Measurements and Instrumentation
Chemical Engineering (CH) 2013

Match the following.

Group 1Group 2
(P) Viscosity(1) Pyrometer
(Q) Pressure(2) Hot wire anemometer
(R) Velocity(3) Rheometer
(S) Temperature(4) Piezoelectric element
Open complete paper
9
2013 · Chemical Engineering · Instrumentation and Process Control · Process Measurements and Instrumentation
Chemical Engineering (CH) 2013
A control valve, with a turndown ratio of 50, follows equal percentage characteristics. The flow rate of a liquid through the valve at 40% stem position is 1 m³/h. What will be the flow rate in m³/h at 50% stem position, if the pressure drop across the valve remains unchanged? (Up to 2 digits after the decimal point.)
Open complete paper
10
2016 · Chemical Engineering · Instrumentation and Process Control · Process Measurements and Instrumentation
Chemical Engineering (CH) 2016
Match the instruments in Group-1 with process variables in Group-2.
Group-1Group-2
P   Conductivity meterI   Flow
Q   Turbine meterII   Pressure
R   Piezoresistivity elementIII   Composition
Open complete paper
11
2016 · Chemical Engineering · Instrumentation and Process Control · Process Measurements and Instrumentation
Chemical Engineering (CH) 2016

What is the order of response exhibited by a U-tube manometer?

Open complete paper
12
2016 · Chemical Engineering · Instrumentation and Process Control · Process Measurements and Instrumentation
Chemical Engineering (CH) 2016
A liquid flows through an “equal percentage” valve at a rate of 2 m3/h when the valve is 10% open. When the valve opens to 20% the flowrate increases to 3 m3/h. Assume that the pressure drop across the valve and the density of the liquid remain constant. When the valve opens to 50%, the flowrate (in m3/h, rounded off to the second decimal place) is ______
Open complete paper
13
2017 · Chemical Engineering · Instrumentation and Process Control · Process Measurements and Instrumentation
Chemical Engineering (CH) 2017

Match the variables in Group-1 with the instruments in Group-2.

Group-1Group-2
P) TemperatureI) Capacitance probe
Q) Liquid levelII) McLeod gauge
R) VacuumIII) Chromatograph
S) ConcentrationIV) Thermistor
Choose the correct set of combinations.
Open complete paper
14
2017 · Chemical Engineering · Instrumentation and Process Control · Process Measurements and Instrumentation
Chemical Engineering (CH) 2017

An LVDT (Linear Variable Differential Transformer) is a transducer used for converting

Open complete paper
15
2019 · Chemical Engineering · Instrumentation and Process Control · Process Measurements and Instrumentation
Chemical Engineering (CH) 2019
A thermocouple senses temperature based on the
Open complete paper
16
2019 · Chemical Engineering · Instrumentation and Process Control · Process Measurements and Instrumentation
Chemical Engineering (CH) 2019
The liquid flow rate through an equal percentage control valve, when fully open, is 150 gal/min and the corresponding pressure drop is 50 psi. If the specific gravity of the liquid is 0.8, then the valve coefficient, \(C_v\), in gal/(min psi0.5) is __________ (rounded off to two decimal places).
Open complete paper
17
2020 · Chemical Engineering · Instrumentation and Process Control · Process Measurements and Instrumentation
Chemical Engineering (CH) 2020
Hot-wire anemometer is used for the measurement of
Open complete paper
18
2020 · Chemical Engineering · Instrumentation and Process Control · Process Measurements and Instrumentation
Chemical Engineering (CH) 2020
Flow of water through an equal percentage valve is 900 liter h-1 at 30% opening, and 1080 liter h-1 at 35% opening. Assume that the pressure drop across the valve remains constant. The flow rate (in liter h-1) through the valve at 45% opening is __________ (round off to nearest integer).
Open complete paper
19
2021 · Chemical Engineering · Instrumentation and Process Control · Process Measurements and Instrumentation
Chemical Engineering (CH) 2021

Which of the following is NOT a standard to transmit measurement and control signals?

Open complete paper
20
2021 · Chemical Engineering · Instrumentation and Process Control · Process Measurements and Instrumentation
Chemical Engineering (CH) 2021
The inherent characteristics of three control valves P, Q and R are shown in the figure.

The CORRECT option(s) is/are

Question diagram

Open complete paper

Showing 20 of 23 questions